| INDIAN
STATNDARDS ON LUMINAIRES AND ILLUMINATING ENGINEERING |
| IS |
PART |
YEAR |
SUBJECT |
REMARK |
| 1777 |
I |
1978 |
Industrial luminaire with metal reflectors,
1st revision, Amendment 1
|
Reaffirned 1990 |
| |
|
|
|
|
| 1913 |
I |
|
General and Sefty requirements for
luminaires |
|
| 1913 |
I |
1978 |
Tubular fluorescent lamps, 2nd edition
|
Reaffirned 1992 |
| |
|
|
|
|
| 1944 |
|
|
Code if Practice for lighting of public
thoroughfares |
|
| 1944 |
I & II |
1970 |
For main an secondary roads (Group
A&B) (1st revision), Amendments 2
|
Reaffirned 1992 |
| 1944 |
V |
1981 |
Lighting for grade separated junctions,
bridges and elivated roads (Group D)
|
Reaffirned 1992 |
| 1944 |
VI |
1981 |
Lighting for town and city centres
and civic importance (Group E)
|
Reaffirned 1992 |
| 1944 |
VII |
1981 |
Lighting for roads with special requirments
(Group F) |
Reaffirned 1992 |
| |
|
|
|
|
| 3287 |
|
1965 |
Industrial lighting fittings with
plastic reflectors Reaffirned 1992
|
Reaffirned 1992 |
| |
|
|
|
|
| 3528 |
|
1966 |
Watreproof electric lighting fittings |
Reaffirned 1990 |
| |
|
|
|
|
| 3553 |
|
1966 |
Watertight electric lighting fittings,
Amendment 1 |
Reaffirned 1990 |
| |
|
|
|
|
| 3646 |
|
|
Code of practic for interior illumonation |
|
| 3646 |
I |
1992 |
General requirements and recommendation
for working interoir, 1st revision
|
|
| 3646 |
II |
1966 |
Schendule for illumination and glare
index |
|
| 3646 |
III |
1966 |
Caluation of coefdficients of utilization
by the BZ method |
|
| |
|
|
|
|
| 4012 |
|
1967 |
Dust-proof electric lighting fittings,
Amendment 1 |
Reaffirned 1990 |
| |
|
|
|
|
| 4013 |
|
1967 |
Dust tigjht electric lighting fittings,
Amendment 1 |
Reaffirned 1990 |
| |
|
|
|
|
| 4347 |
|
1967 |
Code of Practice for industrial lighting |
Reaffirned 1990 |
| |
|
|
|
|
| 6665 |
|
1972 |
Code of parctice for industrial lighting |
Reaffirned 1990 |
| |
|
|
|
|
| 8030 |
|
1976 |
Luminaires for hospitals |
Reaffirned 1992 |
| |
|
|
|
|
| 9583 |
|
1981 |
Emergency lighting units |
Reaffirned 1992 |
| |
|
|
|
|
| 10322 |
|
|
Specification of Luminaires |
|
| 10322 |
I |
1982 |
General requirments |
Reaffirned 1989 |
| 10322 |
II |
1982 |
Constructional requirements |
Reaffirned 1989 |
| 10322 |
III |
1984 |
Screw and screwless terminals |
Reaffirned 1989 |
| 10322 |
IV |
1984 |
Methods of tests |
Reaffirned 1990 |
| 10322 |
V |
1985 |
Particular requirements, Section 1,
General purpose luminaires
|
Reaffirned 1990 |
| 10322 |
V |
1985 |
Particular requirements, Section 2,
Recessed luminiaires |
Reaffirned 1991 |
| 10322 |
V |
1987 |
Particular requirements, Section 3,
Luminaires for road and street lighitng
|
Reaffirned 1992 |
| 10322 |
V |
1987 |
Particular requirements, Section 4,
Portable general purosoe luminaire
|
Reaffirned 1992 |
| 10322 |
V |
1987 |
Particular requirements, Section 5,
Floodlights |
Reaffirned 1992 |
| |
|
|
|
|
|
|
| INDIAN
STANDARDS ON FLAMEPROOF LIGHTING FITTINGS AND ELECTRICAL
INSTALLATION OF LUMINAIRES |
| IS |
PART |
YEAR |
SUBJECT |
REMARK |
| 1885 |
I |
1961 |
Electroechnical Vocabulary |
Reaffirned 1991 |
| |
|
|
|
|
| 2148 |
|
1981 |
Flameproof enclosures of electrical
apparatus, 2nd revision Amedments2
|
Reaffirned 1993 |
| |
|
|
|
|
| 2206 |
I |
1984 |
Well glass and bulkhand types, 1st
revision, Amendment 1 |
Reaffirned 1990 |
| 2206 |
II |
1976 |
Fittings using glass tubes, Amendment
1 |
Reaffirned 1992 |
| |
|
|
|
|
| 4012 |
|
1967 |
Dust-proof electric lighting fittings,
Amendment 1 |
Reaffirned 1990 |
| |
|
|
|
|
| 4013 |
|
1967 |
Dust-tight electic lighting fittings,
Amendment 1 |
Reaffirned 1990 |
| |
|
|
|
|
| 5571 |
|
1979 |
Guide for selection of electrial equipment
for hazardous area, 1st revision,
|
Reaffirned 1990 |
| |
|
|
Amendment 1 |
|
| |
|
|
|
|
| 5572 |
I |
1978 |
Classification of hazardous area (other
than mines) for electrical installations
|
Reaffirned 1991 |
| |
|
|
|
|
| 8224 |
|
1976 |
Electric ilghting for division 2 areas
|
Reaffirned 1992 |
| |
|
|
|
|
| 8240 |
|
1976 |
Guide for electrical equipment for
explosive atmospheres |
Reaffirned 1992 |
| |
|
|
|
|
| 8241 |
|
1976 |
Method of making for identifying electrical
equipment for explosive
|
Reaffirned 1991 |
| |
|
|
atmospher |
|
| |
|
|
Installation of
Luminaires - Indoor and Outdoor |
|
| |
|
|
|
|
| 1554 |
|
|
PVC insulated (heavy
duty) electric cables |
Reaffirned 1992 |
| 1554 |
I |
1988 |
For working voltage upto
and icluding 1100V, 3rd revision |
|
| 1554 |
II |
1988 |
For working voltages
form 3.0000000 kv upto and including 11kV, 2nd revison
|
|
| |
|
|
|
|
| 2309 |
|
1989 |
Code of practice for
the protection of building and allied structure
against lightinf
|
|
| |
|
|
2nd revison |
|
| |
|
|
|
|
| 3043 |
|
1987 |
Code of Practice for
earthing |
Reaffirned 1991 |
| |
|
|
|
|
| 6380 |
|
1984 |
Elastomeric insulation
and sheath of electric cables, 1st
revison
|
Reaffirned 1981 |
| |
|
|
|
|
| 8130 |
|
1984 |
Conductors for insulated
and sheath of electric cables, 1st
revison
|
Reaffirned 1981 |
| |
|
|
|
|
| 9968 |
|
|
Insulated Clabes |
|
| 9968 |
I |
1988 |
For working voltages
uopto and including 1100 V, 1st revision Amendment
1
|
|
| 9968 |
II |
1981 |
Fpr voltages from 33kv
uopto and including 11kV, Amendment 2
|
Reaffirned 1991 |
|
|
| INDIAN
STATNDARDS ON LAMPS AND ACCESSORIES |
| IS |
PART |
YEAR |
SUBJECT |
REMARK |
| 418 |
0 |
1978 |
Tungsten filament general service lamp (third
vision), Amendments 6 |
reaffirmed 1992 |
| |
|
|
|
|
| 1534 |
|
|
Ballasts for flurescent lamps |
|
| 1534 |
1 |
1977 |
For switch startcircuits (2nd revision), Amendm
ents 3 |
reaffirmed 1993 |
| |
|
|
|
|
| 1569 |
1976 |
1976 |
Capacitors for use in tabular fluorescent high
pressure mercury and low pressure sodium vapour
discharge lamp circuits (1st revision) Amendments
1 |
reaffirmed 1990 |
| |
|
|
|
|
| 1885 |
|
|
Electronical Vocabulary |
|
| 1885 |
|
1967 |
Lighting section 3 Lamps & auxililary apparatus |
reaffirmed 1991 |
| |
|
|
|
|
| 2215 |
|
1984 |
Starters for fluorescent lamps (3d version), Amendments
1 |
|
| |
|
|
|
|
| 2418 |
|
1977 |
Tubular fluorescent lamps for general lighting
service |
|
| 2418 |
|
1977 |
Requirements and tests (1st version) Amendments
2 |
reaffirmed 1992 |
| 2418 |
|
1977 |
Standard lapm data sheets (1st version) Amendments
2 |
reaffirmed 1993 |
| 2418 |
|
1977 |
Dimensions of G5 and G 13 bi-pin caps Amendments
1 |
reaffirmed 1990 |
| 2418 |
|
1977 |
Go and no go gauges for G5 and G 13 bi-pin caps
(1st version) |
reaffirmed 1990 |
| |
|
|
|
|
| 3323 |
|
1980 |
Bi-pin lapm holders for tubular fluorescent lamps
(1st version), Amendments 1 |
reaffirmed 1992 |
| 3324 |
|
1982 |
holders for starters for tubular fluorescent lamps
(1st version) |
reaffirmed 1993 |
| |
|
|
|
|
| 6616 |
|
1982 |
Ballasts for high pressure mercury vapour lamps
(1st version) |
reaffirmed 1990 |
| |
|
|
|
|
| 8913 |
|
1978 |
Method of measurement of lamp cap temperature
rise |
reaffirmed 1992 |
| |
|
|
|
|
| 1900 |
|
|
high-pressure mercury vapour lamps |
|
| 1900 |
|
1981 |
Requirements and tests |
reaffirmed 1992 |
| |
|
|
|
|
| 1977 |
|
1981 |
High pressure Sodium Vapour Lmps |
reaffirmed 1992 |
| |
|
|
|
|
| 9974 |
|
1981 |
Specification for SON lamps - General requirements
and tests, Amendments 3 |
reaffirmed 1992 |
| 9974 |
|
1981 |
Standard lamp data sheets, Amendments 2 |
reaffirmed 1992 |
| |
|
|
|
|
| 13021 |
|
|
AC supplied electronic ballast for tubular fluorescent
lamps |
|
| 13021 |
|
1991 |
General and Safety requirements |
|
| 13021 |
|
1991 |
Performance requirements |
|
|
|